Clinical Radiology
Volume 65, Issue 1 , Pages 34-39, January 2010

Unenhanced brain CT is useful to decide on further imaging in suspected venous sinus thrombosis

Department of Radiology, University Hospital K.U. Leuven, Leuven, Belgium

Received 12 May 2009; received in revised form 21 August 2009; accepted 11 September 2009.

Aim

To assess the value of unenhanced brain computed tomography (CT) in the diagnosis of cerebral venous sinus thrombosis (CVST).

Materials and methods

Unenhanced brain CT images of 26 patients with proven CVST were mixed with 26 age and sex-matched images from patients without CVST. Four readers reviewed the 52 brain CT images and were asked to score the examinations for the absence or presence of CVST on a scale from 0 to 4. The mean density in the different venous sinuses was measured by one radiologist.

Results

The sensitivity of unenhanced brain CT for the diagnosis of CVST was 73%. There were no false-positive readings. A receiver-operating characteristic (ROC) analysis on these data resulted in an area under the curve of 0.86. Density measurements proved to be helpful, but could not detect all cases of CVST.

Conclusion

Unenhanced brain CT is a valid initial radiological examination in the diagnosis of CVST. Due to the absence of false-positives in the present series, unenhanced CT can be used to decide whether further imaging with CT angiography or magnetic resonance angiography is required.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0009-9260(09)00353-5

doi:10.1016/j.crad.2009.09.008

Clinical Radiology
Volume 65, Issue 1 , Pages 34-39, January 2010