Clinical Radiology
Volume 63, Issue 10 , Pages 1073-1085, October 2008

The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography

  • A.R. Cowen

      Affiliations

    • LXi_Research, The University of Leeds, Division of Medical Physics, Leeds, West Yorkshire, UK
    • Corresponding Author InformationGuarantor and correspondent: A.R. Cowen, LXi_Research, The University of Leeds, Division of Medical Physics, Worsley Building, Clarendon Way, Leeds LS2 9JT, West Yorkshire, UK. Tel.: +44 0113 3438312.
  • ,
  • A.G. Davies

      Affiliations

    • LXi_Research, The University of Leeds, Division of Medical Physics, Leeds, West Yorkshire, UK
  • ,
  • M.U. Sivananthan

      Affiliations

    • Department of Cardiology, Yorkshire Heart Centre, The General Infirmary, Leeds, West Yorkshire, UK

Received 28 March 2008; accepted 4 June 2008.

Dynamic, flat-panel, solid-state, x-ray image detectors for use in digital fluoroscopy and fluorography emerged at the turn of the millennium. This new generation of dynamic detectors utilize a thin layer of x-ray absorptive material superimposed upon an electronic active matrix array fabricated in a film of hydrogenated amorphous silicon (a-Si:H). Dynamic solid-state detectors come in two basic designs, the indirect-conversion (x-ray scintillator based) and the direct-conversion (x-ray photoconductor based). This review explains the underlying principles and enabling technologies associated with these detector designs, and evaluates their physical imaging characteristics, comparing their performance against the long established x-ray image intensifier television (TV) system. Solid-state detectors afford a number of physical imaging benefits compared with the latter. These include zero geometrical distortion and vignetting, immunity from blooming at exposure highlights and negligible contrast loss (due to internal scatter). They also exhibit a wider dynamic range and maintain higher spatial resolution when imaging over larger fields of view. The detective quantum efficiency of indirect-conversion, dynamic, solid-state detectors is superior to that of both x-ray image intensifier TV systems and direct-conversion detectors. Dynamic solid-state detectors are playing a burgeoning role in fluoroscopy-guided diagnosis and intervention, leading to the displacement of x-ray image intensifier TV-based systems. Future trends in dynamic, solid-state, digital fluoroscopy detectors are also briefly considered. These include the growth in associated three-dimensional (3D) visualization techniques and potential improvements in dynamic detector design.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0009-9260(08)00251-1

doi:10.1016/j.crad.2008.06.002

Clinical Radiology
Volume 63, Issue 10 , Pages 1073-1085, October 2008