Clinical Radiology
Volume 63, Issue 4 , Pages 396-400 , April 2008

Experience with ultrasonographically guided vacuum-assisted resection of benign breast tumors

  • N. Tagaya

      Affiliations

    • Second Department of Surgery, Dokkyo Medical University Mibu, Tochigi, Japan
    • Corresponding Author InformationGuarantor and correspondent: N. Tagaya, Second Department of Surgery, Dokkyo University School of Medicine, 880 Kitakobayashi, Mibu, Tochigi 321-0293, Japan. Tel.: +81-282-87-2158; fax: +81-282-86-6317.
  • ,
  • A. Nakagawa

      Affiliations

    • Second Department of Surgery, Dokkyo Medical University Mibu, Tochigi, Japan
  • ,
  • Y. Ishikawa

      Affiliations

    • Department of Breast and Endocrinological Surgery, Gunma University School of Medicine, Maebashi-shi, Gunma, Japan
    • Department of Pathology, Dokkyo Medical University Mibu, Tochigi, Japan
  • ,
  • T. Oyama

      Affiliations

    • Department of Pathology, Dokkyo Medical University Mibu, Tochigi, Japan
  • ,
  • K. Kubota

      Affiliations

    • Second Department of Surgery, Dokkyo Medical University Mibu, Tochigi, Japan

Received 7 March 2007 ,Revised 22 May 2007 ,Accepted 25 June 2007.

References 

  1. Burbank F, Parker SH, Fogarty TJ. Stereotactic breast biopsy: improved tissue harvesting with the Mammotome. Am Surg. 1996;62:738–744
  2. Meyer JE, Smith DN, DiPiro PJ, et al. Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device. Radiology. 1997;204:575–576
  3. Liberman L, Smolkin JH, Dershaw DD, et al. Calcification retrieval at stereotactic, 11-gauge, directional vacuum-assisted breast biopsy. Radiology. 1998;208:251–260
  4. Burak WE, Owens KE, Tighe MB, et al. Vacuum-assisted stereotactic breast biopsy. Histologic underestimation of malignant lesions. Arch Surg. 2000;135:700–703
  5. Fine RE, Israel PZ, Walker LC, et al. A prospective study of the removal rate of imaged breast lesions by an 11-gauge vacuum-assisted biopsy probe system. Am J Surg. 2001;182:335–340
  6. Simon JR, Kalbhen CL, Cooper RA, et al. Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results. Radiology. 2000;215:694–697
  7. Liberman L, Kaplan JB, Morris EA, et al. To excise or to sample the mammographic target: what is the goal of stereotactic 11-gauge vacuum-assisted breast biopsy?. AJR Am J Roentgenol. 2002;179:679–683
  8. Parker SH, Klaus AJ, Mc Wey PJ, et al. Sonographically guided directional vacuum-assisted breast biopsy using a handheld device. AJR Am J Roentgenol. 2001;117:405–408
  9. Perez-Fuentes JA, Longobardi IR, Acosta VF, et al. Sonographically guided directional vacuum-assisted breast biopsy: preliminary experience in Venezuela. AJR Am J Roentgenol. 2001;177:1459–1463
  10. Chen SC, Yang HR, Hwang TL, et al. Intraoperative ultrasonographically guided excisional biopsy vacuum-assisted core needle biopsy for nonpalpable breast lesions. Ann Surg. 2003;238:738–742
  11. Fine RE, Whitworth PW, Kim JA, et al. Low-risk palpable breast masses removed using a vacuum-assisted hand-held device. Am J Surg. 2003;186:362–367
  12. Baez E, Huber A, Vetter M, et al. Minimal invasive complete excision of benign breast tumours using a three-dimensional ultrasound-guided mammotome vacuum device. Ultrasound Obstet Gynecol. 2003;21:267–272
  13. Moore MP, Kinne DW. Breast sarcoma. Surg Clin North Am. 1996;76:383–392
  14. Philpotts LE, Hooley RJ, Lee CH. Comparison of automated versus vacuum-assisted biopsy methods for sonographicall guided core biopsy of the breast. AJR Am J Roentgenol. 2003;180:347–351

PII: S0009-9260(07)00429-1

doi: 10.1016/j.crad.2007.06.012

Clinical Radiology
Volume 63, Issue 4 , Pages 396-400 , April 2008