Clinical Radiology
Volume 63, Issue 3 , Pages 289-298, March 2008

SPECTCT cerebral perfusion scintigraphy; is the low-dose CT component of diagnostic value?

  • T.V.C. Sulkin

      Affiliations

    • Corresponding Author InformationGuarantor and correspondent: T.V.C. Sulkin, The Royal Cornwall Hospital, Department of Clinical Imaging, The Royal Cornwall Hospital, Truro, Cornwall, UK. Tel.: +44 1872 253095; fax: +44 1872 253030.
  • ,
  • C. Cousens

Department of Clinical Imaging, The Royal Cornwall Hospital, Truro, Cornwall, UK

Received 25 April 2007; received in revised form 12 July 2007; accepted 16 August 2007.

Aim

To assess the potential diagnostic value of the low-dose computed tomography (CT) component of dual-examination single photon emission CT and CT (SPECTCT) cerebral perfusion studies.

Method and materials

Two hundred and forty consecutive 99mTc hexamethylpropylene amine oxime (HMPAO) SPECTCT studies were considered for inclusion. The images were acquired on a hybrid dual-head gamma camera/low-dose CT system. The CT component had a fixed tube current of 2.5mA. The CT section thickness was 5mm and total acquisition time approximately 7.5min. Studies in which no CT images were acquired, or those excessively degraded by movement artefact were excluded. The CT images of each of the remaining studies were retrospectively reviewed and categorized as normal or abnormal. Details of the abnormalities were recorded.

Results

Fifteen of the 240 studies were excluded as no CT images were obtained. A further 14 were excluded as they were considered excessively degraded by movement artefact. A single abnormality was demonstrated on 48 (23%), and two abnormalities on four (2%) of the remaining 211 studies. The most common abnormal findings were low attenuation in the deep cortical white matter (n=22), infarcts (n=12), cerebral atrophy (n=7), dilated ventricles (n=5), basal ganglia calcification (n=4), and post-surgical change (n=3). Other findings included a chronic subdural haematoma, a meningioma, and a posterior fossa cyst. Previous cerebral imaging was available for comparison in 31% of cases. There was 85% concordance between previous imaging and the low-dose CT images.

Conclusion

Twenty-five percent of the low-dose CT images in this study demonstrated abnormalities. Therefore the CT component of cerebral perfusion SPECTCT investigations should be routinely reported in their own right.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0009-9260(07)00373-X

doi:10.1016/j.crad.2007.08.004

Clinical Radiology
Volume 63, Issue 3 , Pages 289-298, March 2008