Clinical Radiology
Volume 62, Issue 12 , Pages 1180-1188, December 2007

Magnetic resonance portal venography: use of fast-acquisition true FISP imaging in the detection of portal vein thrombosis

Department of Radiology, St James Hospital, Dublin 8, Ireland

Received 12 February 2007; received in revised form 18 June 2007; accepted 27 June 2007.

Aim

To determine the accuracy of true fast imaging with steady-state precession (true FISP) in the diagnosis of portal vein thrombosis in patients with cirrhosis and compare it to contrast-enhanced three-dimensional (3D) magnetic resonance (MR) angiography, the reference standard.

Materials and methods

Twenty-four consecutive patients with suspected portal venous thrombosis underwent contrast-enhanced 3D MR angiography and true FISP imaging of the portal vein. All patients had undergone at least one other imaging study, either computed tomography, (CT) or ultrasound. Both sets of MR images were evaluated for patency of the portal venous system and for image quality.

Results

Portal vein thrombosis was diagnosed in six of the 24 patients. Four patients with portal vein thrombosis were accurately diagnosed on the true FISP sequence. This sequence also accurately diagnosed the patency of the portal vein in 17 patients. However, the results were inconclusive in three patients. The image quality of the true FISP sequence of the three inconclusive patients was graded as either poor or fair. Of these three patients, contrast-enhanced 3D MR angiography confirmed portal vein thrombosis in two patients and portal vein stenosis in one patient. True FISP imaging had a sensitivity of 67% and a specificity of 100% for the diagnosis of portal vein thrombosis.

Conclusion

The results of the present study show that the true FISP sequence is useful in diagnosing portal vein thrombosis. It could be employed as an adjunct to contrast-enhanced MR angiography in the severely debilitated patient where respiratory motion may degrade the images or in patients where the use of intravenous contrast medium is not possible due to poor venous access.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0009-9260(07)00282-6

doi:10.1016/j.crad.2007.06.007

Clinical Radiology
Volume 62, Issue 12 , Pages 1180-1188, December 2007